Fully Automatic Flash & Fire point Apparatus:
Determination of the Flash- and Fire-Point with Open Cup - Cleveland Method  (automatic)
AS PER IS 1209: 1978

This flash point and fire-point test method is a dynamic method and depends on definite rates of temperature increases to control the precision of the method.

Its primary use is for viscous materials having a flash point between 79°C (175°F) and 400°C (752°F) except fuel oils, to define the hazards of flammable and combustible materials used in shipping and safety regulations.

The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.

The flash point is the lowest liquid temperature at which application of the flame causes the vapors of the test specimen of the sample to ignite. To determine the fire-point, the test is continued until the application of the test flame causes the test specimen to ignite and sustain burning for a minimum of 5s.

It is an automatic flash and fire-point tester used to examine liquid as well as highly viscous samples in the same instrument without any additional equipment.

For substances with unknown flash points, the APPARATUS has a special search mode program. During the entire heating period, the test flame is moved across the sample at suitable intervals. The expected flash point of a specimen can thereby be found in a time saving and economical manner.

Optional On demand:

When examining highly viscous specimens, a preheating time and temperature are set in order to warm-up and liquefy the sample to inserted temperature probe without problem. Further a skimmer is removing the surface skin from bituminous samples.
Standard Cup with handle, made of brass
Temperature Probe Pt-100 for sample temperature
Electric Gas Igniter with connector cable and plugs
Flame Detection Unit for the detection of flash- and fire-points Flame Arrest Cover for extinguishing the fire in the cup

Specification:

Fully Automatic Flash and Fire point apparatus (by cleaveland open cup method).
  • Temp.Range: Ambient to 400°C with RTD sensor.
  • Flame-Detector: Ionization principle based flame-detector sensor.
  • Stirrer: 60 Rpm, A.C. 230 v, 50 Hz. Synchronous motor.
  • Controller: Microprocessor based process controller cum indicator with 3-wire RTD temperature sensor, free potential flame detector sensor as i/p and 230 v triac as relay o/p.
  • Lid-Closing Motor: 60 Rpm, A.C. 230 v, 50 Hz, synchronous motor for de-combustion.
  • Assembly up/down: Motorized 12 v D.C. jack for ease-of-use.
  • Flame-Sampling Arrangement: 10 Rpm, D.C. 12 v, gear motor, vertical movement reciprocating motion.
  • Heater: 800 W, 230 v.
  • Electrical ignition for flame-sampling. Ignition transformer having continuous o/p of 10.6 Kv. D.C. from 230 v A.C. i/p.
  • Equipment Overall Size (LxWxH): 24”x14”x31”
  • Equipment Gross Weight: 21 Kg.
  • Supply: 230 v, 1-ø, 50 Hz supply with proper earthing system.
Other Products in 'IS/ASTM Test/Measuring Instruments' category
Ductility Apparatus
Ductility Apparatus
Drum Heater
Drum Heater
Digital Penetrometer
Digital Penetrometer
Manual Penetrometer
Manual Penetrometer
 
<< Back


 

Cryostat Water-Bath (Low Temperature)
Cryostat Water-Bath (Low Temperature)
Muffle Furnace of up to 1200°C
Muffle Furnace of up to 1200°C
B.O.D. Incubator
B.O.D. Incubator
Kinematic Viscosity Bath
Kinematic Viscosity Bath
All Glass Water Distillation Unit
All Glass Water Distillation Unit
Reciprocating Water Bath Shakers
Reciprocating Water Bath Shakers
Humidity Controlled Oven
Humidity Controlled Oven
Louvandro Meter
Louvandro Meter
GlassWare Dryer
GlassWare Dryer
Salt Spray Chamber Amended
Salt Spray Chamber Amended
Rapid Oil Extraction
Rapid Oil Extraction
Fully Automatic Vertical Autoclave
Fully Automatic Vertical Autoclave
Stryo Foam Cutter for Oncology
Stryo Foam Cutter for Oncology
Ball Pressure
Ball Pressure
Oil Bath
Oil Bath
Fully Automatic Water Suspan corrected
Fully Automatic Water Suspan corrected
Electrode Drying Oven
Electrode Drying Oven
Portable Electrode Drying Oven With Large Capacity
Portable Electrode Drying Oven With Large Capacity
TC-Test-Machine
TC-Test-Machine
Electrode Oven
Electrode Oven
Ductility Apparatus
Ductility Apparatus
Fully Automatic Flash & Fire Point Apparatus
Fully Automatic Flash & Fire Point Apparatus
Manual Penetrometer
Manual Penetrometer
Drum Heater
Drum Heater
Digital Penetrometer
Digital Penetrometer
 


 
  Contact Details
GLOBAL CORPORATION
A/9, Shukla Estate, Opposite Veena Dalvai Industrial Estate, Off. S.V. Road, Oshiwara, Jogeshwari (W),Mumbai - 400102, Maharashtra, India
Phone:91-22-28993211/26784399/66959625
Fax:91-22-66959625
Send Mail   Send SMS   
Key Personnel
Mr. J. K. Pathak (Proprietor)
Mobile:+919869008159

 


Copyright © 2011-12 by GLOBAL CORPORATION All Rights Reserved.